Selective harmonic mitigation with asymmetrical staircase voltage waveform for a three-phase five-level Cascaded H-Bridge Inverter
2020
Selective harmonics elimination or mitigation strategies are used in all applications where it is necessary to rise the efficiency and reliability of the overall system. This paper presents a simple approach to reduce the low order harmonics amplitude of an asymmetrical staircase voltage waveform for a five-level, three-phase Cascaded H-Bridge Inverter without solving non-linear equations. Through this simple approach, polynomial equations to evaluate the control angels in real-time operations have been found. The effectiveness of the harmonic mitigation method has been tested through the simulation analysis in MatLab/PLECS environment.
Novel Computational Method for Harmonic Mitigation for Three-phase Five-level Cascaded H-Bridge Inverter
2018
The efficiency of the system is a very important parameter for high power electrical drives applications,. Moreover, in the system the efficiency of the power converter play a fundamental role and for this reason, the soft switching modulation techniques represent the best choice. This paper presents a novel computational method for harmonic mitigation on the output voltage of a five-level, three-phase Cascaded H-Bridge Inverter without solving non-linear equations. Through this simple approach the Working Areas have been identified in which the harmonics reference have minimum amplitude possible. Moreover, polynomial equations to evaluate the control angels have been found. In this way, th…